Note:
The grease nipples agree with the standard DIN 71412 or optional DIN
3404.
For the grease quantity, refer to chapter
Technical data
on page 52.
Procedure
1. Add grease to the grease nipples. Refer to the signs on the gear unit. Use a grease
gun.
Install the oil-to-air cooler
Procedure
1. Obey the instructions for the cooling system. Refer to the service manual of the
lubrication and cooling system.
Install the water cooling
Install the water cooling
Note: If the certified drawing does not show the cooling water temperature,
the water flow on the certified drawing is applicable to water at 20 °C (70 °F).
Procedure
1. Obey the instructions for the water cooling system. Refer to the service manual of the
lubrication and cooling system.
Install the oil-to-water cooler
Caution: Make sure that the quality of the cooling water agrees with the
specification in the service manual of the lubrication and cooling system.
Procedure
1. Connect the oil-to-water cooler to the cooling water supply.
8.15
8.16
8.16.1
8.16.2
Installation
42
IM_405_002_EN

Table of Contents

Other manuals for Hansen P4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hansen P4 and is the answer not in the manual?

Hansen P4 Specifications

General IconGeneral
BrandHansen
ModelP4
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals