Operate the gear unit for 5 minutes each 2 weeks
Procedure
1. Operate the gear unit for minimum 5 minutes each 2 weeks. In this condition, the
gear oil prevents corrosion of the internal parts of the gear unit.
Protect the gear unit with a volatile corrosion inhibitor
Procedure
1. Add a volatile corrosion inhibitor to the gear oil. Speak to the supplier of the gear oil
for instructions. Do not add more volatile corrosion inhibitor than specified in section
General specifications for lubricants
on page 61.
2. Seal all openings of the gear unit.
Instructions for operation