Position of the gear unit
Parameter Specification
Inclination Maximum 5 mm per 1 m (5/32 inch per 3 feet or
5 mrad or 17 arc minutes)
Accuracy of the vertical position from the fourth
connection point [mm] ([inch])
0.1 (0.004)
Ambient conditions for storage
Parameter
Specification
Temperature [°C] Above dew point temperature
Relative humidity, non-condensing [%] Maximum 60
General protection Against corrosion and contamination
Vibration Not allowed
Misalignment of the LSS
Parameter
Specification
dr
r
dα
∆α
+
Misalignment equation, where
dr = measured radial misalignment [mm]
Δr = maximum permitted radial misalignment
[mm]
dα = measured angular misalignment [mm]
Δα = maximum permitted angular misalign-
ment [mm]
Smaller than or equal to 1
Misalignment of the HSS (couplings)
Type of coupling
Speed of the HSS [1/min ] Maximum permitted misalign-
ment [mm] ([mils])
Short flexible coupling, radial
misalignment
750 0.19 (7.5)
900 0.15 (6.0)
1000 0.12 (4.8)
1200 0.10 (4.0)
1500 0.09 (3.5)
1800 0.08 (3.0)
Angular misalignment for cou-
pling diameter 100 mm (10
inch)
750 0.13 (13.0)
900 0.10 (10.0)
10000 0.096 (9.6)
1200 0.08 (8.0)
1500 0.07 (7.0)
1800 0.05 (5.0)
13.6
13.7
13.8
13.9
Technical data