Install the cooling coils
Procedure
1. Connect the cooling coil to the
cooling water supply.
2. Make sure that the quality and
water pressure of the cooling water
agrees with the specifications.
Refer to section
Cooling water
specifications
on page 70.
3. While you connect the cooling coil
(A), hold the connection (B) with an
open spanner (C), to prevent
torsion on the cooling coil.
Installation instructions (heater)
Procedure
1. Make sure that the heater automatically goes off if the temperature of the gear oil has
the correct temperature. For the specification, refer to
Additional gear oil
specifications (heater)
on page 61.