Chapter 1 - Overview
1-5
The ability to read the weight seen by each individual
load sensor allows use of this test to make cornering,
leveling and load sharing adjustments to the weighing
system.
AUTO ZERO
TRACKING
Auto Zero Tracking automatically adjusts for zero
weight. This capability allows the module to ignore
material build-up in the weighing system within a pre-
set auto zero tolerance. For auto zeroing to work cor
-
rectly, any “live weight” plus any weight previously
zeroed on the scale must be below the set Auto Zero
Tolerance value and the scale must not be in motion.
This is not used on all applications and should be
reviewed before use.
NOTE: The amount of weight zeroed off is cumulative. The
Autozero command will fail if the current gross weight
plus any previously zeroed amount exceeds the zero
tolerance value.