Chapter 4 - Setup
4-19
Read Parameters
(READPARAM)
Reads all the parameters.
Command Number: 0x69 (Hexadecimal)
Channel Number: 0 or 1
Number of Elements: 8
Return Data:
COMMAND
CHANNEL
•STATUS
PARAMETERS (See Table 4-1)
Read Live Weight
(READLIVEWEIGHT)
Reads gross weight in units set by the Metric Parame-
ter, either lbs or kgs.
Command Number: 0x6B (Hexadecimal)
Channel Number: 0 or 1
Number of Elements: 8
Return Data:
COMMAND
CHANNEL
STATUS = STATUSWORD
Gross weight in units determined by the Metric
Parameters
•Net Weight
Rate of Change
ADC value (A REAL number between 1.0 and
2.0)
Command Table
Command
Number
(Hex)
ZERO* 1