2-4 Duty Cycles
2-9
1
2
3
4
5
6
2) Average speed
From the parameters of N = 140 r/min, ta = 0.03 s, tr = 0.113 s, td = 0.03 s, t = 0.4 s
][r/min64.34
0.578
0.03
2
140
0.113140
0.03
2
140
N
av
=
×
+×
+×
=
As the speed is less than the continuous speed (90 r/min) of RSF-5B-50, it is possible to drive it
continuously on new duty cycle.
Permissible overloaded time
In case RSF supermini series is intermittently operated in allowable continuous torque or more, the
overloaded time is limited by the protective function in the driver even if the duty cycle is allowed. The
limits are shown in the figure below.
RSF-3C
RSF-5B
1
10
100
0.01 0.10 1.00
[Nm]
過負荷検出時間[sec]
RSF-3C-50
RSF-3C-100
RSF-3C-30
Torque [Nm]
Loaded time [s]
RSF-5B-30
RSF-5B-100
RSF-5B-50
Loaded time [s]
Torque [Nm]