48
Clip
HBM A0114-6.3 en
GR201 Limit value switch
Accuracy class 0.1
Differential input
Voltage
Impedance
V
kΩ
" 10
> 50
Reference voltage
coarse approx.
fine approx.
V
V
" 10
" 0.5
Switching hysteresis
Factory setting: R43, R48
to be changed by R43 and R48
mV
kΩ
kΩ
220
3.01
670 mV
V
Hyst.
Influence of a 10K-change in ambient tem-
perature on the switching point
% < 0.05 full scale
Switching-point error % < 0.05 full scale
Relay capacity
max. voltage
max. current
max. power
V
A
W
45 (Protective low voltage)
1
30 (25 VA)
Switching times (Factory setting)
Response time
Releasing time
Use C31a. C34a to change the response or
releasing time
Response time
Releasing time
Use C27. C28 to change the releasing time
only
Releasing time
ms
ms
ms
ms
ms
< 5
< 5
18
.
C31a (C34a) +3
µF
710
.
C31a (34a) +3
µF
6
.
C27 (C28) +3
µF
Operating voltage V DC +15 ... 30
Power consumption mA < 100 (20 mA no relay closed)
Nominal temperature range °C - 20 ... + 60
Service temperature range °C - 20 ... + 60
Storage temperature range °C - 25 ... + 70
Degree of protection IP20
Weight g 200