EasyManua.ls Logo

Hettich UNIVERSAL 32 R - FU; CCI - ERROR 63: FC Overcurrent; FU; CCI - ERROR 64: FC Intermediate Circuit Voltage; FU; CCI - ERROR 67: Motor Overtemperature (115 V); FU; CCI - ERROR 68: FC Overtemperature

Default Icon
49 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CP : control panel, FC : frequency converter, SB : supply board, CB : cooling board, CC : control cable, LL : lid locking, BC : braking chopper,
BR : brake resistor, MR : mains reset
20/49
FU / CCI - ERROR 63
Error cause Overcurrent.
Error remedy
Short circuit in motor.
Motor impedance is too low.
CC is defective.
FC is defective.
FU / CCI - ERROR 64
Error cause Voltage in intermediate circuit:
>410 V DC at 230 V
>205 V DC at 115 V
This error normally only occurs when the drive is being braked.
Error remedy
BR is defective.
CC is defective.
FC is defective.
Measurement Also see at FC, U
DC.
FU / CCI - ERROR 67
Error cause Only centrifuges with 115 V.
Overtemperature in the motor. The cable “overtemperature” in
the motor has high impedance.
Error remedy
Overtemperature switch opens because of overtemperature
in the motor
CC is defective.
FC is defective.
Motor is defective
Measurement Also see at FC, remove plug S2 and measure at the plug
Switch closed: 0
opened:
FU / CCI - ERROR 68
Error cause Overtemperature in FC.
Error remedy
Insufficient heat abduction from FC to centrifuge housing.
There is no, or not enough, heat-conducting paste between
FC and housing.
Full-load operation and an ambient temperature > 45°C.
CC is defective.
FC is defective.

Table of Contents