4.5.2. Crane with remote control [option]
A remote-controlled crane cannot be operated from the main control valve, but only through a
controller.
The stabiliser legs can be operated by the main control valve from both sides of the crane.
Stabilisers extension can be operated only manually.
The main control valve becomes the control station only for emergency operation (refer to the
section “Emergency operation” for more information).
Lever Component Lever position Movement
(S) Stabiliser leg
Up
Down
4.6. SCANRECO controller [option]
The SCANRECO controller system consists of:
• a controller unit with buttons/selectors and levers
• a receiver
• an emergency cable
• two batteries
• a battery charger and its accessories
• a belt/shoulder strap
The controller normally communicates with the crane
through the receiver via radio, but it can also be used with
a cable (when the batteries are discharged or when the use
of radio frequencies is forbidden).
The Operating system
EFFER 35 45