Page 54 October 2013
© 2013 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
DTC1250e/DTC1000Me/DTC4250e Card Printer User Guide, PLT-01668, 1.0
Window TAB Procedure Procedure (continued)
Reverse Bit Order is used to reverse
the character bits and is used for the
encryption of data in specific programs
Add Leading Zeros is used to
add a set number of leading
zeros to the magnetic string in
order to move the starting
point of the encoded data in
specific programs for
encryption of data.
4.11.2 Magnetic Track Options
The magnetic Encoding Module encodes onto tracks in accordance with an ISO 7811-2 Magnetic Stripe.
For track locations, review the display below. Tabs are available on the Magnetic Encoding tab with
options for encoding data on each track.
Reviewing the ISO Track Locations
TRACK1 0.110"
TRACK2 0.110"
TRACK3 0.110"
0.130"
0.140"
0.223" 0.353" 0.493"
Reviewing the Sample String
Track 1: ~1%JULIEANDERSON^1234567890?
Track 2: ~2;1234567890987654321?
Track 3: ~3;1234567890987654321?
Track
Start
Sentinel
End Sentinel
Field
Separator
Valid Characters
Maximum
Number of
Characters
Track 1
% ? ^
ASCII 32-95
(See the table below.)
78
Track 2
; ? =
ASCII 48-63
(See the table below.)
39
Track 3
; ? =
ASCII 48-63
(See the table below.)
106

Table of Contents