February 2016 L000950, Version: 4.0
Page 4-15 To o lB ox
Lamination Card Backup
This option changes the distance a card backs up after lamination pressure is
first applied.
Lamination Card Length This option dictates card length and should not be adjusted.
Lamination Fan Speed
This option adjust the fan speed level to replicate printer fan speed control.
• 0 = 100%
• 1 = 75%
• 2 =50%
• 3 = 25%
Lamination Peel Off Delay This option adjust the delay between lamination stage and peel off stage.
Warming Time Delay
The setting adjusts how many additional minutes the printer will wait after
the transfer roller reaches temperature before beginning transfer.
The range is 0 to 20 minutes.
Enable Ribbon and Film
Saving
This setting enables power up ribbon/film savings.
When enabled, the ribbon and film will not skip to a new set of panels after a
power up.
Cover open/close behavior is unaffected, so upon a cover close, the ribbon
and film will skip a set of panels.
Settings are:
• Disabled (0) (default)
• Enabled (1)
Input Hopper Home Offset
This setting adjusts the position of the shuttle when in the home position.
The range is 0 to 30.
The larger the number the closer to the front of the printer the shuttle will be
placed. The printer must be rebooted for this setting to take effect.
Input Hopper Mag Offset
This setting adjusts the position of the shuttle when in the mag position.
The range is -20 to 20.
The larger then number the closer to the front of the printer the shuttle will
be placed. The printer must be rebooted for this setting to take effect.
Transfer Image Length
This setting adjusts the length of the image on the card during transfer.
The range is -10 to +10.
The larger the number, the longer the image.
Transfer Cooling Delay
This setting adjusts the delay (in seconds) before transferring to the second
side of the card.
The range is 0 to 180. The larger the number, the longer the delay in seconds.
Ribbon Factory Take-up
This setting corrects motor speed variation of the ribbon take-up motor.
The range is -20 to +20.
The larger the value the faster the motor goes.
Note: This is a factory setting, the user should never adjust this.
Ribbon Factory Supply
This setting corrects for motor speed variation of the ribbon supply motor.
The range is -20 to +20.
The larger the value the faster the motor goes.
Note: This is a factory setting, the user should never adjust this.
Setting Description