4.7.2 Value outside the range error message
If typing a value outside the range, an error message will display specific to the setting.
Note: The ## will correspond to the correct number per the setting.
Film Factory Take-up
This setting corrects for motor speed variation of the film take-up motor.
The range is -20 to +20.
The larger the value the faster the motor goes.
Note: This is a factory setting, the user should never adjust this.
Film Factory Supply
This setting corrects for motor speed variation of the film take-up motor.
The range is -20 to +20.
The larger the value the faster the motor goes.
Note: This is a factory setting, the user should never adjust this.
Transfer Delay
This option adds a delay (in millisecond) between when the card is queued
for transfer and the start of transfer.
This setting can be set between 0 and 1500, with each unit adding a
1 millisecond delay
Durable Cooling Delay
This setting adjusts the delay (in seconds) before transferring the second
side of the card when Clear High Durable HDP Film is installed.
This setting can be set between 0 and 600, with each unit adding a
1 second delay.
Durable Film Print Cooling
Level
This option adds an offset to the transfer roller temperature when Clear High
Durable HDP film is installed.
Durable Film Trans Cooling
Level
This option controls the fan speed and on-times of the transfer cooling fan
during transfer when Clear High Durable HDP Film is installed.
Setting Description

Table of Contents