Once the temperature has been increased 4 times (20 degrees), reset
temperature to default and increase the Dwell Time by .5 second.
Repeat this process until adequate adhesion is achieved.
Ensure that the cards (in use) have a surface roughness (Ra) of 60 micro
inches or less.
This information should be available from the card manufacturer.