GigE Line Scan Camera·User Manual
38
Figure 7-30 Trigger Debouncer Sequence Diagram
Click Digital IO Control > Line Debouncer Time, and set Line Debouncer Time according to actual
demands.
Figure 7-31 Set Line Debouncer Time
When the configured debouncer time is larger than trigger signal time, and the trigger signal
will be ignored.
The unit of line debouncer time may differ by device models.
The sequence diagram above uses rising edge as trigger activation.