If the triggered device needs a LVTTL of 3.3 V and below, the wiring is shown below.
Triggered
Device
Camera Power
PWR
Camera Power Ground
GND
LINE*N
LINE*P
Power Ground of Trigger Device
Hang
Signal Line
Figure 9-18 Single-Ended Output Wiring without Pull-Up Resistor
If the triggered device needs a LVTTL of 5 V and above, you should add a pull-up resistor
between 1 KΩ and 10 .
The voltage of VCC should be matched with the trigger voltage.
Triggered
Device
Camera Power
PWR
VCC
Camera Power Ground
GND
LINE*P Signal Line
R (1 KΩ to 10 KΩ)
LINE*N Hang
Power Ground of Trigger Device
Figure 9-19 Single-Ended Output Wiring with Pull-Up Resistor