GigE Line Scan Camera·User Manual
70
1
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0
1
0.90.80.70.6
0.50.40.3
0.2
0
0.1
0.1
Gamma=1
Gamma=0.5
Gamma=2
Gamma=4
Figure 10-30 Gamma Curve
There are 2 types of Gamma correction, including User mode and sRGB mode. You can set User
mode as shown below.
Steps:
1. Click Analog Control > Gamma Selector.
2. Select User as Gamma Selector.
3. Enable Gamma Enable.
4. Enter Gamma according to actual demands, and its range is from 0 to 4.
Figure 10-31 Set User Mode
You can set sRGB mode as shown below.
Steps:
1. Click Analog Control > Gamma Selector.
2. Select sRGB as Gamma Selector.
3. Enable Gamma Enable.