EasyManua.ls Logo

HIKVISION AX DS-PWA32-HSR

HIKVISION AX DS-PWA32-HSR
121 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault Check
The system determines whether to check the faults listed on the page. The system will only check
the fault that is selected.
Click System → System
Opons → Control Panel Fault Checklist to enter the page.
Detect Network Camera Disconnecon
If the opon is enabled, when the linked network camera is disconnected, an alarm will be
triggered.
Baery Supervision
If the opon is enabled, when baery is disconnected or out of charge, the device will upload
events.
Wired Network Fault Check
If the opon is enabled, when the wired network is disconnected or with other faults, the alarm
will be triggered.
Wi-Fi Fault Check
If the
opon is enabled, when the Wi-Fi is disconnected or with other faults, the alarm will be
triggered.
Cellular Network Fault Check
If the opon is enabled, when the cellular data network is disconnected or with other faults, the
alarm will be triggered.
SIM Card Fault Check
If the
opon is enabled, the alarm will be triggered for faults of the SIM card.
AC Power Down Check Time
The system checks the fault aer the congured me duraon aer AC power down.
To compliant the EN 50131-3, the check me duraon should be 10 s.
Time
Sengs
You can set the device me zone, synchronize device me, and set the DST me. The device
supports me synchronizaon via Hik-Connect server.
Time Management
Click System → Date and Time to enter the Time Management page.