To migrating and expanding:
1. Enter the Physical Disk interface by going to Menu > System Configuration > RAID > Physical
Disk to confirm at least one available physical disk has existed for the array migration.
2. Select Array tab to enter the Array interface.
3. Select the array to be migrated and click to enter the Migrate Array interface.
Figure 117 Migrate Array Interface
4. Select the available physical disk and click OK to confirm the settings.
5. There will pop up an attention box with these words: Do not unplug the physical disk when it is
under rebuilding. Click OK to start rebuilding.
6. You can enter the Array interface and Virtual Disk interface to check the process of the migration.
Figure 118 Array Interface
Figure 119 Virtual Disk Interface
7. Reboot the device to take effect of the new setting after the migration process finished.
8. Enter the HDD Information interface after rebooting by going to Menu > System Configuration >
HDD > HDD Information.
9. Select an expandable virtual disk and click the Expand button to expand the capacity of the
virtual disk.