Access Control Terminal·User Manual
27
Figure 6-23 Door Settings Interface
3. Edit door parameters.
Open Time: Door action time, set the door action time: 1 ~ 255 s.
Open Time-out : Delayed door alarm, set the delayed door alarm threshold:
0 ~ 255s.
Door Magnetic: Door magnetic status settings, Remain open and remain
closed are selectable.
Button Type: Exit button status settings, Remain open and remain closed
are selectable.
First Card: Set whether to enable the first card function, which is keeping
the door open with the first card.
4. Click the # key to confirm the settings.
6.3.4 Settings Authentication Mode
In this section, you can set the controller authentication mode for opening the
door, that is, Card Only, and Card & Password.
Steps:
1. Move the cursor to Mode (Authentication Settings) by using direction keys
in the system settings interface.
Figure 6-24 Authentication Settings Interface
2. Click the # key to select the authentication mode.