Select an authencaon mode according to your actual needs from the drop-down list.
Authencaon Interval
You can set the authencaon interval of the same person when authencang. The same
person can only authencate once in the congured interval. A second authencaon will be
failed.
Alarm of Max. Failed
Aempts
Enable to report alarm when the card reading aempts reach the set value.
Max.
Authencaon Failed Aempts
Enable to report alarm when the card reading aempts reach the set value.
Communicaon with Controller Every
When the access control device cannot connect with the card reader for longer than the set
me, the card reader will turn oine automacally.
Note
The authencaon interval value ranges from 2 s to 255 s.
Set Door Parameters
Click Conguraon → Access Control → Door Parameters .
Click Save to save the
sengs aer the conguraon.
Door No.
Select Entrance or Exit for sengs.
Door Name
You can create a name for the door.
Open Duraon
Set the door unlocking duraon. If the door is not opened for the set me, the door will be
locked.
Note
The open duraon ranges from 5 s to 60 s.
Exit Buon Type
You can set the exit buon as Remain Open or Remain Closed according to your actual needs.
By default, it is Remain Open.
Door Remain Open
Duraon with First Person
Set the door open duraon when rst person is in. Aer the rst person is authorized, it allows
mulple persons access the door or other authencaon acons.
DS-K3G501X Series Tripod Turnsle