Figure 7-16 Elevator Control
2.
Check to enable elevator control funcon.
3.
Select an Elevator No., and select an elevator controller type for the elevator.
4.
Set the
Negave Floor.
5.
Select the Interface Type as RS-485 or Network Interface. And enable the elevator control.
-
If you select RS-485, make sure you have connected the door staon to the elevator controller
with RS-485 wire.
-
If you select Network interface, enter the elevator controller's IP address, port No., user
name, and password.
6.
Click Save to enable the
sengs.
Note
●
Up to 4 elevator controllers can be connected to one door staon.
●
Up to 10 negave oors can be added.
●
Make sure the interface types of elevator controllers, which are connected to the same door
staon are consistent.
RS-485 Sengs
Set the working mode to linked device.
Steps
1.
Click Access Control → RS-485 to enter the sengs page.
Video Intercom Face Recognion Door Staon User Manual