Enable the funcon and set the arming start me. The zone will be armed according to the
congured me.
Note
The auto arming
me and the auto disarming me cannot be the same.
The buzzer beeps slowly 2 minutes before the auto arming starts, and beeps rapidly 1
minute before the auto arming starts.
You can select to enable forced arming on the System Opons page. While the funcon is
enabled, the system will be armed regardless of the fault.
If the public area is enabled, the area 1 dose not support auto arming.
Enable Auto Disarming
Enable the funcon and set the disarming start me. The zone will be disarmed according to
the
congured me.
Note
The auto arming
me and the auto disarming me cannot be the same.
If the public area is enabled, the area 1 dose not support auto disarming.
Late to Disarm
Enable the funcon and set the me. If the alarm is triggered aer the congured me, the
person will be considered as late.
Note
You should enable the Panel Management Nocaon funcon in Communicaon
Parameters → Event Communicaon before enabling the Late to Disarm funcon.
Weekend Excepon
Enable the funcon and the zone will not be armed in the weekend.
Excepted Holiday
Enable the funcon and the zone will not be armed/disarmed in the holiday. You should set
the holiday schedule
aer enabling.
Note
Up to 6 holiday groups can be set.
Sounder Delay Time (Perimeter Alarm)
If you have set the perimeter zone, you can set the delayed me for the zone.
Note
The available me duraon range is from 0 s to 600 s.
Alarm Duraon