Installation BAT
Release
05
03/2013
65
EMC
Stability
Radio standards
EMC interference
immunity
EN 61000-4-2 Electrostatic discharge
Contact discharge: test level 3
Air discharge: test level 3
6 kV
8 kV
EN 61000-4-3 Electromagnetic field, test level 3
- 80 - 2000 MHz
- 2000 MHz - 2700 MHz
10 V/m
3 V/m
EN 61000-4-4 Fast transients (burst), test level 3
- Power line
- Data line
2 kV
1 kV
EN 61000-4-5 Voltage surges
- Power line, line/line: test level 2
- Power line, line/ground: test level 3
- Data line: test level 3
0,5 kV
1 kV
1 kV
EN 61000-4-6 Conducted interference voltages, test level 3
150 kHz - 80 MHz 10 V
EMC emitted
interference
EN 55022 Class B
FCC 47 CFR Part 15 Class B
Stability
Vibration IEC 60068-2-6 Test FC test level according to IEC 61131-2
IEC 60068-2-64 test level in accordance with EN 50155
Shock IEC 60068-2-27 Test Ea test level in accordance with IEC 61131-2,
EN 50155
Shock resistance
BAT54-F X2 and
BAT54-F X2 FCC
IEC 60079-0
Shock resistance test with 1kg mass dropped from 0.7 m
Housing cover only removeable with tool
EN 300 328 Electromagnetic compatibility and radio spectrum matters (ERM) -
bandwidth transfer systems - data transmission equipment operating in
2.4 GHz ISM band and using spread spectrum modulation technology
EN 301 893 Broadband radio access networks (BRAN) – 5 GHz high performance
Remote Local Area Network (RLAN)
EN 301 489-1 Electromagnetic compatibility for radio equipment and services
EN 301 489-17 Electromagnetic compatibility (EMC) for radio equipment and services -
specific conditions for 2.4 GHz broadband transmission systems and 5
GHz high-performance RLAN equipment
EN 302 502 Broadband radio access networks (BRAN) – permanently installed
broadband data transmission systems with 5.8 GHz band