Installation BAT
Release
05
03/2013
7
Operate the device at the specified surrounding air temperature
(temperature of the surrounding air at a distance of up to 1.97 in (5 cm)
from the device) and relative air humidity specified in the technical data.
When you are selecting the installation location, make sure you
observe the climatic threshold values specified in the technical data.
Use the device in an environment within the pollution degree specified
in the technical data.
Note:
Relevant for BAT-Rail types: Environmental rating: open type
For use in ordinary locations, NFPA 70.
Relevant for BAT-F types: Environmental rating: Type 1 (indoor use only).
For use in NFPA 79 applications only.
When installing external antennas, adhere to the regulations of the
country in which you are operating the WLAN device.
In ambient temperatures under -10 °C, use cabling designed for
minimum temperatures.
Relevant for use in Ex zone 2 according to ATEX 95 (ATEX 100a):
Only products labeled accordingly may be operated in Ex zone 2.
When operating the BAT-300F X2 types in Ex zone 2, the following
applies:
II 3G
Ex nA IIC T4 Gc, -20 °C ... +55 °C
KEMA 10ATEX0124 X
DO NOT OPEN WHEN ENERGIZED.
When operating the BAT-54F X2 types in Ex zone 2, the following applies:
II 3G
Ex nA IIC T4 Gc, -20 °C ... +60 °C
KEMA 07ATEX0190
DO NOT OPEN WHEN ENERGIZED.
The BAT-300/54F X2 types are installed with a housing cover - as
mounted in the state on delivery.
Temperature Code T4 Ambient -20 °C … +55 °C
List of Standards EN 60079-0: 2009
EN 60079-15: 2010
Temperature Code T4 Ambient -20 °C … +60 °C
List of Standards EN 60079-0: 2009
EN 60079-15: 2010