Installation BAT
Release
05
03/2013
When operating the BAT54/300-Rail types in Ex zone 2, the following
applies:
II 3G
Ex nA IIC T4 Gc, -30 °C ... +50 °C
DEKRA 11ATEX0007 X
DO NOT OPEN WHEN ENERGIZED.
DO NOT USE THE 12 VDC INPUT, WHEN OPERATING THE DEVICE
IN HAZARDOUS LOCATIONS.
Relevant for use in Hazardous Locations (Class 1 Division 2):
Only products labeled accordingly may be operated in Class 1 Division 2
Hazardous Locations.
When operating the BAT54/300-Rail FCC types in Class 1 Division 2
Hazardous Locations, the following applies:
CLASS I; DIV. 2
GROUPS A; B; C AND D
TEMPERATURE CODE T4
AMBIENT -30 °C ... +50 °C
List of Standards: FM3600, FM3611
DO NOT OPEN WHEN ENERGIZED.
DO NOT USE THE 12 VDC INPUT, WHEN OPERATING THE
DEVICE IN HAZARDOUS LOCATIONS.
Special conditions for safe use
Provisions shall be made to prevent the rated voltage from being
exceeded by transient disturbances of more than 40 %.
When the temperature under rated conditions exceeds 70 °C at the
cable or conduit entry point, or 80 °C at the branching point of the
conductors, the temperature specification of the selected cable shall
be in compliance with the actual measured temperature values.
Temperature Code T4 Ambient -30 °C … +50 °C
List of Standards EN 60079-0: 2009
EN 60079-15: 2010