Installation MACH104
Release
07
07/2014
19
1.6 Management interfaces
1.6.1 V.24 interface (external management)
The V.24 interface is an RJ11 socket.
The V.24 user interface is serial and allows you to connect the following
devices directly:
External management station (VT100 terminal or PC with appropriate
terminal emulation). With this management station, the Command Line
Interface (CLI) is available to you. Furthermore, the system monitor is
available to you at the system start.
An AutoConfiguration Adapter ACA 11
The socket housing is electrically connected to the front panel of the device.
The V.24 interface is not electrically isolated from the supply voltage.
Figure 8: Pin assignment of the V.24 interface and the DB9 connector
Note: You will find the order number for the terminal cable, which is ordered
separately, in the Technical Data section (see on page 30 “Technical data”).
LED Display Color Activity Meaning
LS Link status None Device detects an invalid or
missing link
Green Lights up Device detects a valid link
Flashes 1 time a period Port is switched to stand-by
Flashes 3 times a period Port is switched off
DA Data traffic Yellow Flashing Device is transmitting and/or
receiving data
VT 100 terminal settings
Speed 9,600 Baud
Data 8 bit
Stopbit 1 bit
Handshake off
Parity none
1
1
8
5
6
2
3
5
1
2
3
4
5
6
CTS
n.c.
TX
GND
RX
RTS
RJ11
DB9
RJ11
DB9