3 Making basic settings
The IP parameters must be entered when the device is installed for the first
time. The device provides the following options for configuring IP addresses:
Input via the V.24 interface
Input via the HiView or Industrial HiVision application. You find further
information about the applications HiView or Industrial HiVision on the
Internet at the Hirschmann product pages:
HiView
http://www.hirschmann.com/en/QR/INET-HiView
Industrial HiVision
http://www.hirschmann.com/en/QR/INET-Industrial-HiVision
Configuration via BOOTP
Configuration via DHCP (Option 82)
AutoConfiguration Adapter
You will find more information in the “Basic Configuration User Manual”.
The manual is available for download on the Internet: https://
www.doc.hirschmann.com
Default settings
IP address: The device looks for the IP address using DHCP
Password for management:
Login: user; password: public (read only)
Login: admin; password: private (read and write)
Parameters that can be set via the management are set to pre-defined
values in accordance with the MIB
V.24 data rate: 9600 Baud
Ring redundancy: disabled
Ethernet ports: link status is not evaluated (signal contact)
Optical 100 Mbit/s ports: 100 Mbit/s full duplex
All other ports: autonegotiation
Ring manager disabled
Stand-by coupling: disabled
Port 4 = control port, port 3 = coupling port for red. Ring coupling