Climatic conditions
during operation
Minimum clearance around the
device
Top and bottom sides of device: 1.97 in
(5 cm)
Left and right device side: 3.94 in
(10 cm)
Ambient air temperature
a
. Standard: 0 °C ... +60 °C (+32 °F ...
+140 °F)
b
Extended: -40 °C ... +70 °C (-40 °F ...
+158 °F)
b
Humidity 5 % ... 95 % (non-condensing)
Air pressure up to 6562 ft (2000 m; 795 hPa)
higher altitudes upon request
Climatic conditions
during storage
Ambient air temperature
a
Extended: -40 °C ... +70 °C (-40 °F ...
+158 °F)
Extended: -40 °C ... +85 °C (-40 °F ...
+185 °F)
b
Humidity 5 % ... 95 % (non-condensing)
Air pressure up to 6562 ft (2000 m; 795 hPa), higher
altitudes upon request
Pollution degree 2
Protection classes Laser protection
Protection class
Class 1 according to EN 60825-1
IP30