84
Installation MSP30/32/40/42 and MSM20/22/24/40/42/46/50
Release
12
06/2018
a. EN 61131-2, CE, FCC – applies to all devices
b. Merchant Navy – applies to devices with the certification codes VU, U9, UY, UW, UX
c. EN 50121-4 – applies to devices with the certification codes VT, T9, TY
d. EN 61850-3, IEEE 1613 – applies to devices with the certification codes V9, VY, VU, VT
e. Media modules MSM2x-T5T5T5T5...HH: 6 kV
Stability Standard
applications
a
a. EN 61131-2, CE, FCC – applies to all devices
Merchant Navy
b
b. Merchant Navy – applies to devices with the certification codes VU, U9, UY, UW, UX
Railway applications
(trackside)
c
c. EN 50121-4 – applies to devices with the certification codes VT, T9, TY
Substation
applications
d
d. EN 61850-3, IEEE 1613 – applies to devices with the certification codes V9, VY, VU, VT
IEC 60068-2-6, test Fc Vibration 5 Hz ... 8.4 Hz with
0.14 in. (3.5 mm)
amplitude
2 Hz ... 13.2 Hz with
1 mm amplitude
e
e. Applies to device variants featuring customer-specific version with the characteristic value HH
— 2 Hz ... 9 Hz with 0.11 in
(3 mm) amplitude
8.4 Hz ... 150 Hz with
1g
—
13.2 Hz ... 200 Hz
with 0.7 g
e
—
—
—
9 Hz ... 200 Hz with 1 g
200 Hz ... 500 Hz with
1.5 g
— 2 Hz ... 25 Hz with
1.6 mm amplitude
f
f. Applies to device variants featuring customer-specific version with the characteristic value HX
——
— 25.0 Hz ... 100 Hz
with
4g
f
——
IEC 60068-2-27, test Ea Shock 15 g at 11 ms — — 10 g at 11 ms