107
phenomena cause measure remark
ignition system
,no spark
1.switch lock
carve out a way or
short circuit,connection
badness
line bonding
badness
2.CDI set
After electrify no
noise from the CDI
3.high voltage
high voltage lead
insulated badness
high voltage lead
carve
out a way or short circuit
4. magneto
signal loop and charge
loop
carve out a way or short
circuit
repair
repair
replace
repalce
repalce
repalce
2.
spark weak
or sparkove
r
intermittence
1. spark plug
pollute or wear
intermittence
2. high voltage bag
high voltage lead wire
insulated badness
repalce
replace
electrification
system
1,
discharge
self
2, uncharge or
shortage-charge
1. cover polluted or
drenched by rain
1.
carve out a way or short
circuit, caused by
connected wire badness
2.
rectifier damaged
3.baterry
lower-
electrolyte
electrode failure
water-proof,keep
clean of the
cover and repalce
electrolyte
repair
repalce
entered distilled
water
replace
flash not
bright or weak
, horn sound
1. the switch of flash lamp
or
emergency light
contacted badness
2. lamp
filament of lamp
damaged
the watt of lamp larger
or smaller than regulated
number
3.
routing
repair or
replace
replace
replace