107
phenomena cause measure remark
ignition system
1,no spark
1.switch lock
※
carve out a way or
short circuit,connection
badness
※
line bonding
badness
2.CDI set
※ After electrify no
noise from the CDI
3.high voltage
※ high voltage lead
insulated badness
※high voltage lead
carve
out a way or short circuit
4. magneto
※ signal loop and charge
loop
carve out a way or short
circuit
★repair
★repair
★replace
★repalce
★repalce
★repalce
2.
spark weak
or sparkove
r
intermittence
1. spark plug
※ pollute or wear
intermittence
2. high voltage bag
※high voltage lead wire
insulated badness
★repalce
★replace
electrification
system
1,
discharge
self
2, uncharge or
shortage-charge
1. cover polluted or
drenched by rain
1.
carve out a way or short
circuit, caused by
connected wire badness
2.
rectifier damaged
3.baterry
※lower-
electrolyte
※
electrode failure
★
water-proof,keep
clean of the
cover and repalce
electrolyte
★repair
★repalce
★
entered distilled
water
★replace
1. flash not
bright or weak
2
, horn sound
1. the switch of flash lamp
or
emergency light
contacted badness
2. lamp
※
filament of lamp
damaged
※ the watt of lamp larger
or smaller than regulated
number
3.
routing
★ repair or
replace
★replace
★replace