Installing Precautions 2-2
Upward printing
Lateral printing
Downward printing
Print head
cable included
1m
1.5m
Print head
Print head cable
Main body installation surface
IJ printer
main body
Print head
Print head cable
Bend R
0.5m
Connect a duct to this port
(50 mm in diameter).
Exhaust duct
connection port
(9) When installing the print head and print head cable, comply with the following conditions.
When positioning the end of the print head above the printer main body installation surface,ensure
that the distance between the end of the print head and the installation surface does not exceed 1.5 m.
When positioning the end of the print head below the printer main body installation surface, ensure
that the distance between the end of the print head and the installation surface does not exceed 1 m.
2
1
(10) When using the printer for upward or lateral printing, ensure that the rising print head cable upper end
is positioned not more than 0.5 m above the print head.
(11) If you fixed the print head, ensure that the minimum bend radius of the print head cable is at least 150 mm.
Handle the headcable with care when wiring it.
If the minimum bend radius is less than 150mm, the tubes and wires inside the headcable might be broken.
(12) The ink stream may bend for some reason or other (due, for instance, to dirt).
The facilities positioned in the direction of ink ejection should be partially covered as needed to avoid ink
accumulation.
(13) When connecting an exhaust duct to the printer, install a damper and adjust the wind velocity at the intake
port to 0.3 to 0.5 m/s. (Use an anemometer for verification. If the wind velocity is too high, the makeup