iv
Index to Warnings and Cautions in This Manual
Cautions and Warnings for Orientation and Mounting Procedures
Wiring - Warnings for Electrical Practices and Wire Specifications
CAUTION: Hazard of electrical shock. Disconnect incoming power
before working on this control. Wait five (5) minutes before removing the
front cover.
....... 2–3
CAUTION: Be sure to install the unit on flame-resistant material such as
a steel plate. Otherwise, there is the danger of fire.
....... 2–9
CAUTION: Be sure not to place any flammable materials near the
inverter. Otherwise, there is the danger of fire.
....... 2–9
CAUTION: Be sure not to let the foreign matter enter vent openings in
the inverter housing, such as wire clippings, spatter from welding, metal
shavings, dust, etc. Otherwise, there is the danger of fire.
....... 2–9
CAUTION: Be sure to install the inverter in a place that can bear the
weight according to the specifications in the text (Chapter 1, Specifica-
tions Tables). Otherwise, it may fall and cause injury to personnel.
....... 2–9
CAUTION: Be sure to install the unit on a perpendicular wall that is not
subject to vibration. Otherwise, it may fall and cause injury to personnel.
....... 2–9
CAUTION: Be sure not to install or operate an inverter that is damaged
or has missing parts. Otherwise, it may cause injury to personnel.
....... 2–9
CAUTION: Be sure to install the inverter in a well-ventilated room that
does not have direct exposure to sunlight, a tendency for high tempera-
ture, high humidity or dew condensation, high levels of dust, corrosive
gas, explosive gas, inflammable gas, grinding-fluid mist, salt damage,
etc. Otherwise, there is the danger of fire.
....... 2–9
CAUTION: Be sure to maintain the specified clearance area around the
inverter and to provide adequate ventilation. Otherwise, the inverter may
overheat and cause equipment damage or fire.
..... 2–10
WARNING: “Use 60/75°C Cu wire only” or equivalent. ..... 2–15
WARNING: “Open Type Equipment. ..... 2–15
WARNING: “Suitable for use on a circuit capable of delivering not more
than 5,000 rms symmetrical amperes, 240 V maximum.” For models with
suffix N or L.
..... 2–15

Table of Contents

Other manuals for Hitachi L200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi L200 Series and is the answer not in the manual?

Hitachi L200 Series Specifications

General IconGeneral
Output Frequency0.1-400Hz
CommunicationRS-485 (Modbus RTU)
Frequency Range0.1-400Hz
Operating Temperature-10°C to +50°C
Storage Temperature-20°C to +65°C
Input Voltage200-240V
Control MethodV/f control, Sensorless vector control
Overload Capacity150% for 60 seconds
ProtectionOvercurrent, overvoltage, undervoltage, overload, overheating, short circuit
Output Voltage3-phase, 0 to input voltage
Cooling MethodForced air cooling
Humidity5% to 95% RH (non-condensing)
AltitudeUp to 1000m without derating
Braking UnitBuilt-in braking transistor (for models up to 7.5kW), External braking resistor can be connected