2.2 ADDITIONAL INFORMATION ABOUT SAFETY
! DANGER
Do not pour water into the indoor or outdoor unit. These
products are equipped with electrical parts. If water contacts
with electrical components then it will cause a serious electrical
shock.
Do not touch or adjust safety devices inside the indoor or
outdoor units. If these devices are touched or adjusted, it may
cause a serious accident.
Do not open the service cover or access the indoor or outdoor
units without disconnecting the main power supply.
In case of re Turn OFF the main switch, put out the re at once
and contact your service contractor.
! CAUTION
• Do not use any sprays suchas insecticide, lacquer, hair spray or
otherammablegaseswithinapproximatelyone(1)meterfromthe
system.
• If circuit breaker or fuse is often activated, stop the system and
contactyourservicecontractor.
• Do not make service or inspections tasks by yourself. This works
mustbeperformedbyqualiedserviceperson.
• Donotputanystrangematerial(sticks,etc...)intotheairinletand
outlet.Theseunitshavehighspeedrotatingfansanditisdangerous
thatanyobjecttouchesthem.
• Refrigerant leakage can cause difculty with breathing due to
insufcientair.
• This appliance must be used only by adult and capable people,
having received the technical information or instructions to handle
properlyandsafelythisappliance.
• Childrenshouldbesupervisedtoensurethattheydonotplaywith
theappliance.
? NOTE
Itisrecommendedtoventilatetheroomevery3or4hours.
3 IMPORTANT NOTICE
The supplementary information about the purchased
products is supplied in a CD-ROM, which can be found
bundled with the outdoor unit. In case that the CD-ROM is
missing or it is not readable, please contact your Hitachi
dealer or distributor.
• PLEASE READ THE MANUAL AND THE FILES ON
THE CD-ROM CAREFULLY BEFORE STARTING WORK
ON THE INSTALLATION OF THE AIR CONDITIONING
SYSTEM. Failure to observe the instructions for installation,
use and operation described in this documentation may
result in operating failure including potentially serious faults,
or even the destruction of the air conditioning system.
Verify, in accordance with the manuals which appear in the
outdoor and indoor units, that all the information required for
the correct installation of the system is included. If this is not
the case, contact your distributor.
Hitachi pursues a policy of continuing improvement in design
and performance of products. The right is therefore reserved
to vary specications without notice.
Hitachi cannot anticipate every possible circumstance that
might involve a potential hazard.
This air conditioner has been designed for standard air
conditioning for human beings. For use in other applications,
please contact your Hitachi dealer or service contractor.
No part of this manual may be reproduced without written
permission.
If you have any questions, contact your service contractor of
Hitachi.
This manual should be considered as a permanent part of
the air conditioner. This manual gives a common description
and information for this air conditioner which you operate
as well as for other models.
Check and make sure that the explanations of each part of
this manual correspond to your air conditioner model.
Refer to the models codication to conrm the main
characteristics of your system.
Signal words (NOTE, DANGER and CAUTION) are used
to identify levels of hazard seriousness. Denitions for
identifying hazard levels are provided below with their
respective signal words.
These operations modes are controlled by the remote
control switch.
! DANGER
Pressure Vessel and Safety Device: This air conditioner is equipped
with a high pressure vessel under PED (Pressure Equipment
Directive). The pressure vessel has been designed and tested before
shipment according to PED. Also, in order to prevent the system
from an abnormal pressure, a high pressure switch, which needs no
eld adjustment, is utilized in the refrigeration system. Therefore,
this air conditioner is protected from abnormal pressures. However,
if abnormally high pressure is applied to the refrigeration cycle
including the high pressure vessel(s), it will result in serious injury
or death due to explosion of the pressure vessel. Do not apply a
pressure higher than the following pressure to the system, by
modifying or changing the high pressure switch.
! CAUTION
This unit is designed for commercial and light industrial application.
If installed in house hold appliance, it could cause electromagnetic
interference.