1.3.9 Remote Operation Transmission 
1.3.9-1 Text 
 
 
 
 
 
 
 
 
 
 
1.3.9-2 Types of control 
 
Types of control for operation 
Starts to jet ink and shifts from stop status to 
ready status. 
(Same process as with <Startup> button) 
Stops ink jet, and shifts to stop status (Same 
process as with <Shutdown> button) 
When ink is being jetted 
(Standby, ready status, 
etc.) 
Deflection 
voltage control 
(ON) 
Turns deflection voltage on 
(Same process as with <Ready> button in 
Manual control menu window) 
Deflection 
voltage control 
(OFF) 
Turns deflection voltage off 
(Same process as with <Standby> button in 
Manual control menu window) 
Closes the window for any fault that has 
occurred. 
However, the window will remain if the cause of 
fault is not resolved. 
 
●Specify only one category of control at a time. 
●Even if executing function is not possible, ACK will be answered, but no function will be executed. 
 
 
 
   
Type 
30H: Operation start 
31H: Operation stop 
32H: Deflection voltage control (ON) 
33H: Deflection voltage control (OFF) 
34H: Fault clear