63
1.6.4 Errors
(1) Errors during external communications
Errors during print content transmission and print data call-up
No.
Condition
Type of error
1
Not all received print contents could be held in
buffer because its capacity was exceeded
NAK is returned.
However, this will not cause any
external communication error.
2
Number of print items of received contents is
more than 9. Or, received contents consist of
more than 81 characters.
External communication error 030
3
Calendar or count character was included in print
data call-up transmission
External communication error 027
4
When print content was transmitted to the item
number(s) which does NOT exist.
External communication error 027
Error when buffer is cleared
No.
Condition
Type of error
1
Text was transmitted together with another text
External communication error 002
(2) Errors during printing
Errors during printing
No.
Condition
Type of error
1
The number of received contents in buffer was
less than "Data number at Fault".
Fault "Communication Buffer Fault"
(Ink ejection does not stop)
2
Print start signal was received during print data
switching immediately after ACK was returned to
"restart printing"
Fault "Invalid Data Change Timing"
(3) Error when status is changed
Error when status is changed
No.
Condition
Type of error
1
Calendar characters or count characters were included
to existing print contents when restored to online.
Confirmation message
"Communication buffer error"