Loading...
No. Item Description
3 Date, time* The date, time and the time dierence between UTC and the
local time in the format of "YYYY-MM-DD-Thh:mm:ss.s ±
hh:mm".
YYYY: year, MM: month, DD: day
hh: hour, mm: minute, ss.s: second in one decimal place.
± hh:mm: hours and minute of the time dierence. "Z" is
displayed instead of "± hh:mm" when there is no time
dierence between UTC and the local time, such as
"2005-12-26T:23:06:58.0Z".
4 Detected
location
The host name (SVP).
5 Program name The detection entity identier (Storage).
6 Process name The process name (-).
7 Message ID The message ID (-).
8 Structured data The structured data (-).
9 Unied
specication
identication
The unied specication identier (CELFSS).
10 The revision number of the unied specication document
(1.1).
11 Message
identication
The serial number of the syslog header information.
12 Type of audit
event
The category name of the event.
Authentication of RMI, FC-SP, or Device Manager - Storage
Navigator.
CongurationAccess indicates setting from Device
Manager - Storage Navigator, SVP or host.
Maintenance indicates SVP operations.
AnomalyEvent indicates reached the maximum of the
Audit Log, etc.
ExternalService indicates remote maintenance operations
through SVP.
13 Result of audit
event
Success: Normal end. The operation has ended normally.
Failed: Error (xxxx-yyyy). The operation has ended
abnormally.
Failed: Warning (xxxx-yyyy). The operation has partly ended
abnormally or was canceled during the operation.
Syslog
Chapter 1: Failure monitoring
Hitachi Alert Notication Guide for VSP5000 Series 16

Table of Contents