Trap reference
code
Description Section Alert level
Host
report
1
SIM
22
SIM
23
SIM
13
db dx xx Drive Link Rate Abnormality Drive error SERVICE Yes
db ex xx Drive Link Rate Abnormality Drive error SERVICE Yes
db fx xx Drive Link Rate Abnormality Drive error SERVICE Yes
dc 0x xx PAIR SUSPEND(RIO PATH
CLOSE)
Failure
with paired
volumes
SERIOUS Yes
5
dc 1x xx PAIR SUSPEND(MVOL ERROR) Failure
with paired
volumes
SERIOUS Yes
5
dc 2x xx PAIR SUSPEND(RVOL ERROR) Failure
with paired
volumes
SERIOUS Yes
5
dc 4x xx PAIR SUSPEND(SUSPEND
REPORT)
Failure
with paired
volumes
SERIOUS Yes
5
dc 5x xx PAIR SUSPEND(SIMPLEX
REPORT)
Failure
with paired
volumes
SERIOUS Yes
5
dc 6x xx PAIR
SUSPEND(COMMUNICATION
ERROR AT RCU)
Failure
with paired
volumes
SERIOUS Yes
5
dc 7x xx PAIR SUSPEND(ERROR
DETECTED AT RCU)
Failure
with paired
volumes
SERIOUS Yes
5
dc 8x xx A volume being used by an S-
VOL was suspended (PS OFF
on the MCU side was
detected)
Failure
with paired
volumes
SERVICE No
dc 9x xx ERASE FAIL Failure
with paired
volumes
SERIOUS Yes
5
dc ax xx Pair suspend (Spread by error
of another Aliate)
Failure
with paired
volumes
SERIOUS Yes
5
Failure trap reference codes
Chapter 8: SIM codes