Trap reference
code
Description Section Alert level
Host
report
1
SIM
22
SIM
23
SIM
13
da 4x xx A change to an S-VOL was
received from the RCU (An
instruction to delete a pair was
received in the Duplex status.)
Failure
with paired
volumes
SERVICE No
da 5x xx A change to an S-VOL was
received from the RCU (A pair
deletion was completed.)
Failure
with paired
volumes
SERVICE No
da 6x xx A change to an S-VOL was
received from the RCU (An
instruction to delete a pair was
received in the Hold status.)
Failure
with paired
volumes
SERVICE No
db 0x xx Drive port temporary error Drive error SERVICE Yes
db 1x xx Drive port temporary error Drive error SERVICE Yes
db 2x xx Drive port temporary error Drive error SERVICE Yes
db 3x xx Drive port temporary error Drive error SERVICE Yes
db 4x xx Drive port blockade Drive error MODERAT
E
Yes
db 5x xx Drive port blockade Drive error MODERAT
E
Yes
db 6x xx Drive port blockade Drive error MODERAT
E
Yes
db 7x xx Drive port blockade Drive error MODERAT
E
Yes
db 8x xx LDEV blockade (Eect of Drive
port blockade)
Drive error SERIOUS Yes
db 9x xx LDEV blockade (Eect of Drive
port blockade)
Drive error SERIOUS Yes
db ax xx LDEV blockade (Eect of Drive
port blockade)
Drive error SERIOUS Yes
db bx xx LDEV blockade (Eect of Drive
port blockade)
Drive error SERIOUS Yes
db cx xx Drive Link Rate Abnormality Drive error SERVICE Yes
Failure trap reference codes
Chapter 8: SIM codes
Hitachi Alert Notication Guide for VSP5000 Series 80