OPERATING THE ENGINE
3-7
CHECK INSTRUMENTS AFTER STARTING
Checking instruments through monitor functions.
After starting the engine, check the following points through
the monitor functions.
Check that
1. Alternator indicator (1) is off.
2. Engine oil pressure indicator (2) is off.
3. Engine noise and exhaust gas are normal.
IMPORTANT: Prevent possible damage to engine. If in
-
dicator lights do not go out after starting
engine, IMMEDIATELY STOP THE ENGINE and
correct the cause.
Operate machine at less-than-normal loads
and speeds until the engine is at normal
operating temperature.
1
2
M1U1-03-002