File System 8-8
© 2005 HMS Industrial Networks AB7607 User manual
The contents of this file can be redirected by placing the line ‘[File path]’ on the
first row, and a file path on the second.
Example:
[File path]
\user\eth_settings.cfg
In this example, the settings described above will be loaded from the file
‘user\eth_settings.cfg’.
This permits normal users to access the network configuration settings.
Note: The module needs to be restarted for changes in this file to have affect.
‘ip_accs.cfg’
It is possible to configure which IP addresses and what protocols that are allowed
to connect to the module. This information is stored in the file ‘\ip_accs.cfg’. The
file contains one or several of the headers below.
[Web]
[FTP]
[Telnet]
[Modbus/TCP]
[Ethernet/IP]
[All]
Under each header the allowed IP addresses are written. The wildcard ‘*’ can be
used to allow series of IP addresses. If a protocol header is not given, the system
will use the configuration set under the header ‘All’. If the ‘All’ header is not
given, the protocol will not accept any connections.