File System 8-7
© 2005 HMS Industrial Networks AB7607 User manual
Configuration Files
‘ethcfg.cfg’
This file contains the network configuration and is read by the module at start up.
The settings in this file are affected by SSI commands.
The components and format of the file is shown below:
[IP address] IP address
10.10.12.212
[Subnet mask] Subnet mask
255.255.255.0
[Gateway address] Gateway address
0.0.0.0
[SMTP address] SMTP address – This must be configured in
0.0.0.0 order to send emails
[DHCP/BOOTP] DHCP/BootP ‘ON’-Enabled, ‘OFF’-Disabled
OFF
[Speed] Speed ‘Auto’ Autonegotiation will be used
Auto ’100’ Forces the module at 100mbits
‘10’ Forces the module at 10mbits
[Duplex] Duplex ‘Auto’ Autonegotiation will be used
Auto ’Full’ Forces the module to operate only at full duplex.
’Half’ Forces the module to operate only at half duplex.