File System 8-9
© 2005 HMS Industrial Networks AB7607 User manual
Example:
[Web]
10.10.12.*
10.10.13.*
[FTP]
10.10.12.*
[Telnet]
10.10.12.*
[All]
*.*.*.*
The above example will allow all IP addresses beginning with 10.10.12 to access
all protocols in the module. IP numbers beginning with 10.10.13 will not be able
to access the FTP and Telnet servers. The Modbus/TCP and EtherNet/IP servers
will accept connections from any IP address. The contents of this file can be redi-
rected by placing the line ‘[File path]’ on the first row, and a file path on the sec-
ond.
Example:
[File path]
\my_settings\ip_access_rights.cfg
In this example, the settings described above will be loaded from the file
‘\my_settings\ip_access_rights.cfg’.
Note: The module has to be restarted in order for any changes in this file to have
affect.