. A complete Parts List is available at www.HobartWelder.com
OM-923 Page 19
SECTION 6 − OPERATION
6-1. Controls
1 Material Thickness Selector
Switch
Use switch to select the material
thickness range. Do not switch
under load.
. Switch must “click” into detent
position for weld output.
2 Power Switch
Ref. 230 001-B
18 ga
16 ga
16 ga
12 ga
12 ga
10 ga
10 ga
3/16”
DO NOT SWITCH
WHILE WELDING
2
1
6-2. Operating The Gun
Ref. 804 240-A
1 Trigger Switch
The trigger must be pressed to
weld. Wire does not feed and is not
energized until trigger is pressed.
1