EasyManua.ls Logo

Honeywell 8680i

Honeywell 8680i
252 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
46 8680i User Guide
Good Read Delay
This sets the minimum amount of time before the 8680i can read another bar code.
Default = 0 ms (No Delay).
User-Specified Good Read Delay
If you want to set your own length for the good read delay, scan the bar code below,
then set the delay (from 0 - 30,000 milliseconds) by scanning digits, then the Save
bar code from the Programming Chart on page 235.
Manual Trigger Modes
When in manual trigger mode, the 8680i scans until a bar code is read, or until the
trigger is released. Two modes are available, Normal and Enhanced. Normal mode
offers good scan speed and the longest working ranges (depth of field). Enhanced
mode gives you the highest possible scan speed but slightly less range than Nor-
mal mode. Enhanced mode is best used when you require a very fast scan speed
and don’t require a long working range. Default = Manual Trigger-Normal.
* No Delay
Short Delay (500 ms)
Medium Delay (1,000 ms)
Long Delay (1,500 ms)
User-Specified Good Read Delay

Table of Contents

Other manuals for Honeywell 8680i

Related product manuals