60 8680i User Guide
You would use the same command line as shown in Output Sequence Example 2 -
Three Symbologies with <> Separators (page 58):
SEQBLK sequence editor start command
62 code identifier for Code 39
9999 code length that must match for Code 39, 9999 = all
lengths
43 start character match for Code 39, 43h = "C"
FF termination string for first code
6A code identifier for Code 128
9999 code length that must match for Code 128, 9999 = all
lengths
54 start character match for Code 128, 54h = “T”
FF termination string for first code
72 code identifier for PDF417
9999 code length that must match for PDF417, 9999 = all
lengths
4D start character match for PDF417, 4Dh = “M”
FF termination string for third code
SEQSEP99 separator for each sequence, 99 = all symbologies
3C left bracket (<)
3E right bracket (>)
SEQSUF99 separator for suffixes, 99 = all symbologies
0D carriage return
0A line feed
And you would add >PARTIAL< as the prefix to note the partial sequence:
SEQTTS1 transmit partial sequence
SEQISU99 add partial sequence prefix, 99 = all symbologies