22 69-2245EF
Vacancy Heating Setpoint
This parameter is the heating setpoint when the thermostat is in Vacancy mode (see
page 4).
Vacancy Cooling Setpoint
This parameter is the cooling setpoint when the thermostat is in Vacancy mode (see
page 4).
Minimum Floor Limit
This parameter is available only if the thermostat is configured in AF mode (see page 19).
Heating
is activated, regardless of setpoint, if the floor temperature is equal to this setting or below.
Maximum Floor Limit
This parameter is available only if the thermostat is configured in AF mode (see page 19)
.
Heating
is disabled, regardless of setpoint, if the floor temperature is equal to this setting or above.
Default setting 41 °F (5 °C)
Range between the minimum and maximum setpoints
Default setting 81 °F (27 °C)
Range between the minimum and maximum setpoints
Default setting 41 °F (5 °C)
Range 41 °F (5 °C) to 100 °F (38 °C)
Default setting 100 °F (38 °C)
Range 41 °F (5 °C) to 100 °F (38 °C)
400-146-001-A_69-2245EF (AQ1000TP2) ENG.fm Page 22 Wednesday, June 18, 2008 2:32 PM

Table of Contents

Other manuals for Honeywell AQ25A Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell AQ25A Series and is the answer not in the manual?

Honeywell AQ25A Series Specifications

General IconGeneral
BrandHoneywell
ModelAQ25A Series
CategoryControl Panel
LanguageEnglish

Related product manuals