Sensor options: Sensor enable/disable, set span concentration values, set calibration interval, set
bump interval, set alarm setpoints, set STEL interval, set TWA period, auto zero at startup
enable/disable, 5% overspan, low alarm acknowledge, oxygen measurement, and combustible
gas measurement
Maximum hose length for sampling: 75 ft (22 m)
Maximum hose length for calibration: 3 ft (0.9 m)
Battery operating time: One rechargeable lithium polymer battery at 20°C provides 13 hours
operating runtime
Year of manufacture: The detector’s year of manufacture is determined from the serial number.
The first and second number after the first two letters determines the year of manufacture.
Example: MA110-001000 = 2010 year of manufacture
Approved battery for GasAlertMaxXT II product:
Lithium-ion polymer (MA-BAT01) as per standards EN 60079-,UL913, CSA C22.2 No. 157
Rechargeable battery (MX-BAT01) Temperature Code
Lithium Polymer -20°C ≤ Ta ≤ +50°C T4
Battery charger: Honeywell BW™ MaxXT II Charging Adapter
First-time charge: 6 hours
Normal charge: 6 hours
Warranty: 2 years including sensors
Approvals
Approved by CSA to both U.S. and Canadian Standards
CAN/CSA C22.2 No. 157 and C22.2 152
ANS/UL – 913 and ANSI/ISA – S12.13 Part 1
CSA Class I, Division 1, Group A, B, C, and D
ATEX
CE 0539 II 1 G Ex da ia IIC T4 Ga
KEMA 08 ATEX 0001
EN 60079-0, EN 60079-1, EN 60079-11
IECEx
Ex da ia IIC T4 Ga CSA 07.0012
IEC 60079-0, IEC 60079-1, IEC 60079-11
INMETRO Ex da ia IIC T4 Ga DNV 12.0135
KYL 12-KB4BO-0054
a
UKCA 21UKEX0050
IP IP66/IP67
a. http://www.honeywellanalytics.com/~/media/honeywell-analytics/products/gasalertmax-
xtii/documents/certifications/koreanexcertificate_bw_gamaxxtii_12kb4bo0054.pdf?la=en
BW MaxXT II 105 User Manual