Button
Button Description
l
To activate the detector press .
l
To deactivate the detector, press and hold until the OFF
countdown is complete and the LCD deactivates.
l To view the date/time, TWA, STEL, and maximum (MAX) readings, press
twice rapidly. To clear the TWA, STEL, and MAX readings, press
when the LCD displays CLEAR ALL.
l
To initiate calibration, press and hold as the detector performs the
OFF countdown. Continue holding while the LCD briefly
deactivates and then reactivates to begin the CAL countdown. Release
when the CAL countdown is complete.
l
To activate the backlight, press and release.
l
To acknowledge the latched and pump alarms, press .
l To acknowledge a low alarm and disable the audible alarm temporarily,
press . The Low Alarm Acknowledge option must be enabled in
Safety Suite Device Configurator (SSDC)
l To acknowledge any of the Due Today alarms (calibration, bump test,
pump block test), press .
BW MaxXT II 13 User Manual