Appendix F - CTL table format
Part No.: 4417584_Rev12 Configuration Manual
CIU 888 F - 36
$*6
APPENDIX F CTL TABLE FORMAT
Refer to the below table for the CTL Table format.
NOTE: This table supports up to 1000 CTL points.
CTL Table Example Description
[PRODUCT_ID]
Name = Petrol ASCII string: the name of
the Liquid
Date = 01-06-92 ASCII string: the date this
file is generated
Time = 11:05:16 ASCII string: the time this
file is generated
Temperature = 20
CTL = 6
CTLPoints = 50
[CTL_POINTS]
1 = 15.556 2.0000
2 = 16.111 0.9998
3 = 16.667 0.9995
4 = 17.222 0.9992
5 = 17.778 0.9989
6 = 18.333 0.9987
7 = 18.889 0.9984
8 = 19.444 0.9982
. . . .
. . . .
. . . .
. . . .
. . . .
50 = 42.778 0.9873
[EOF] [End Of File]